Technical information
76
MITSUBISHI ELECTRIC
INVERTER
/// INVERTER
MITSUBISHI
The ultra compact FR-D700 series fre
-
quency conver ters excel through their
very s imple operation whilst still provid
-
ing many functions.
The spring clamp controller connections
version enables simple and fast set-up of
the frequency inverter.
The FR-D700 is equipped with a safety
stop func tion.
The small dimensions render the
FR-D700 series frequency inver ters ideal
for use in restric ted spaces. New func-
tionssuchasintermediatecircuitcontrol
of the ouput frequenc y, the dancer roll
control or the traverse func tion,
facilitate universal use in numerous
applications such as
앬
Pumps
앬
Fans
앬
Presses
앬
Conveyor belts
앬
Industrial washing machines
앬
Automatic shelf systems
The frequency inverters FR-D720S EC are
for single-phase use 200 to 240 V AC.
The FR-D740 EC frequency inverters are
designed for 3-phase connec tions 380 to
480 V AC.
FR-D700
Remarks:
햲
The applicable motor capacityindicated is themaximum capacityapplicablefor useof the Mitsubishi 4-pole standard motor.
햳
The rated output capacity indicated assumes that theoutput voltageis 440V.
햴
The%valueoftheoverloadcurrentrating indicated is the ratio of the overload current to the inverter's rated output current.
For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.
햵
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changedwithin the setting range. However, the pulsevoltage value
of theinverter output side voltage remains unchanged at about Ö2
that of the power supply.
햶
The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
Product line
FR-D720S EC FR-D740 EC
008 014 025 042 070 100 012 022 036 050 080 120 160
Output
Applicablemotor capacity
햲
kW 0.1 0.2 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Rated capacity
햳
kVA——————1.22.03.04.67.29.113.0
Rated current A 0.8 1.4 2.5 4.2 7.0 10.0 1.2 2.2 3.6 5.0 8.0 12.0 16.0
Overload capacity
햴
150 % of rated motor capacity for 60 s; 200 % for 0,5 s
Voltage
햵
3phase, 0 V up to power supply voltage
Input
Power supply voltage 1phase, 200–240V AC, -15 %/+10% 3phase, 380–480 V AC, -15 %/+10 %
Voltage range 170–264 V AC at 50/60 Hz 325–528 V AC at 50/60 Hz
Frequencyrange 50/60Hz±5% 50/60Hz±5%
Rated input capacity
햶
kVA——————1.52.54.55.59.512 17
Control-
specifi-
cations
Control method V/fcontrol, optimum excitation control or general-purpose magnetic flux vector control
Modulation control Sine evaluated PWM, Soft PWM
PWM switching frequency kHz 0.7–14.5, user adjustable
Frequency range Hz 0.2–400
Possible starting torque ³ 150 % / 1 Hz (for vector control oderslip compensation)
Torque boost Manual torque boost
Acceleration / deceleration time 0.1 to 3600 s
Acceleration / deceleration
characteristics
Linear or S-pattern acceleration/deceleration mode selectable
Brems-
moment
DC braking Operating frequency: 0–120 Hz, operating time: 0–10 s, voltage: 0–30 %(externallyadjustable)
Motor protection Electronic motor protection relay (rated current useradjustable)
Control
signals for
operation
Frequency setting signal 0–5 V DC, 0–10 V DC, 0/4–20 mA, From control panel (parameter unit). Frequency setting increment is selectable.
Input signals
Any of 5 signals can be selected using parameters 178 to 182 (input terminal function selection): multi-speed selection, remote setting, second function selection,terminal 4 input
selection, JOG operation selection, PID control valid terminal, external thermal input, PU-external operation switchover, V/F switchover, output stop, start self-holding selection,
traverse function selection, forwardrotation, reverse rotationcommand, inverter reset, PU-NET operation switchover, external-NET operation switchover, command source
switchover, inverter operation enable signal, and PU operation external interlock
Operation functions
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after instantaneous power failure operation, for-
ward/reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip compensation, operation mode selection,offline auto tun-
ing function, PID control, computer link operation (RS-485), optimum excitation control, power failure stop, speed smoothing control,Modbus-RTU
Output
signals
operation status
Can beselected usign parameters 190and 192(output termnalfunctionselection): inverter operation, up-to-frequency, overload alarm, output frequencydetection,regenerative
brake prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID lower limit,PID upper limit, PID for
-
ward/reverserotation output, fan alarm, heatsinkoverheatpre-alarm, deceleration at an instantaneous power failure,PID control activated,PID output interruption, during retry,
life alarm, currentaverage value monitor,remote output, alarm output, fault output, fault output 3, and maintenance timer alarm
analog signal 0–10V DC
Others
Dimensions (WxHxD)
68 x 128 x
80.5
68 x 128 x
80.5
68 x 128 x
142.5
68 x 128 x
162.5
108 x 128 x
155.5
140 x 150 x
155.5
108 x 128 x
80.5
108 x 128 x
80.5
108 x 128 x
80.5
108 x 128 x
80.5
108x128x
80.5
220 x 150 x
155
220 x 150 x
155
Order informat ion
Art. no. 214189 214190 214191 214192 214193 214194 212414 212415 212416 212417 212418 212419 212420
Automation Book_UK_2008.prn
Automation Book_UK_2008
Dienstag, 8. April 2008 18:24:37
Farbprofil: Deaktiviert
Komposit Standardbildschirm