Technical information

74
MITSUBISHI ELECTRIC
INVERTER
/// INVERTER
Mitsubishi's comprehensive range of frequency
inverters offers a wealth of benefits for the user,
making it easy to choose the perfect solution for
every drive application. With most Mitsubishi
Frequency Inver ters an overload capacity of
200 % is standard. This means they deliver dou
-
ble the per formance of the competing inver ters
with the same rating. Mitsubishi Electric inver t
-
ers also have active current limiting. This pro
-
vides the perfect response characteristics of
the current vector system and gives you the confi
-
dence you need for demanding drive applications.
The system instantly identifies over currents and
limits them automatically with its fast response,
allowing the motor to continue operating nor
-
mally at the current threshold.
Mitsubishi inverters are also able to communi
-
cate with industry standard bus systems like
Profibus/DP, DeviceNet, CC-Link, CANopen,
LON Network , RS 485/Modbus RTU making it
possible to integrate frequency inverters as part
of a complete automation system.
Mitsubish i inver te rs are real ene rgy savers
achieving maximum drive capacity utilisation
with minimum power consumption. Flux opti
-
misation ensures that the connected motor
only gets exactly the amount of magnetic flux
required for optimum efficiency. This is particu
-
larly important at low speeds as motors are nor
-
mally using a voltage/frequency control system.
FREQUENCY INVERTERS
Feature FR-D700 FR-S500E FR-E700 FR-E500 FR-F700 FR-A700
Rated motor output range
0,1–7,5 kW 0.2–3.7 kW 0,4–15 kW 0.4–7.5 kW 0.75–630 kW 0.4–630 kW
Frequency range
0,2–400 Hz 0.5–120 Hz 0,2–400 Hz 0.2–400 Hz 0.5–400 Hz 0.2–400 Hz
Power supply
Single phase,
200–240 V (-15 %/+10 %)
Three-phase,
380–480 V (-15 %/+10%)
Single phase,
200–240 V (-15 %/+10 %)
Three-phase,
380–480 V (-15 %/+10%)
Three-phase,
380–480 V ( -15%/+10 %)
Single phase,
200–240 V (-15 %/+10 %)
Three-phase,
380–480 V (-15 %/+10 %)
Three-phase,
380–480 or 500 V (-15 %/+10
%)
Three-phase,
380–480 or 500 V(-15 %/+10
%)
Protection
IP 20 IP 20 IP 20 IP 20
FR-F700: IP 00 / IP 20
FR-F746: IP54
IP 00/ IP 20
Special functions
V/f control
Sensorless vector control
Brake transistor
Safety stop function
conforming EN 954-1 Cat3
Energy saving control
(Optimum exitation control)
Maintenance timer
V/f control
V/f control
Real sensorless vector
control
Brake transistor
Safety stop function
conforming EN 954-1 Cat3
Torque limit
Ext. brake control
Flying start
Remote I/O
Maintenance timer
V/f control
Magnetic flux vector control
Traverse function
Switch motor to direct
mains
operation
Advanced PID function
(multi pump function)
Regeneration avoidance
function
Flying start
V/f control
Simple magnetic flux vector
control
Life time diagnostics
Torque control
Positon control
Real sensorless vector
control
Closed loop vector control
Traverse function
Regeneration avoidance
function
Integrated PLC function
Easy gain tuning
Life time diagnostics
Specifications
Refer to page 76 Refer to page 77 Refer to page 78 Refer to page 79 Refer to page 80 Refer to page 82
F740
0kW
55 kW 630 kW
0.75 630 kW
Larger kW ratings available up to 900kW
on request
A740
0.4 630 kW
Three Phase
E540/D740
S540E
S520SE
0.4 7.5 kW
0.4 2.2 kW
E520S
0.4 3.7 kW
Single Phase
F746
0.75–55kW
0.2 1.5 kW
Larger kW ratings available up to 900kW
on request
E740
0.4–15kW
.
RUN
RUN
SET
MODE
PU
EXT
PU
EXT
STOP
RESET
FR-S500
MITSUBISHI
MITSUBISHI
Hz
A
PU
RUN
MON
EXT
RUN
STOP
RESET
Hz
MON
MITSUBISHI
PU
REV
REV
SET
EXT
PU
EXT
STOP
RESET
NET
FWD
FWD
MODE
P.R U N
FR-DU07
FR–A740–2.2K
DANGER:Risk of injur y and electric shock
CAUTION:Risk of fire
Read the manual and follow the safetyinstructions before use.
Isolate from supply and wait 10 minutes before removingthis cover.
Ensure proper earth connection
Mount the inverter on a non-combustible surface.
A
V
FR-A 700
400V
!
!
Hz
MON
MITSUBISHI
PU
REV
REV
SET
EXT
PU
EXT
STOP
RESET
NET
FWD
FWD
MODE
P.R U N
FR-DU07
FR–F740–2.2K
DANGER:Risk of injur y and electric shock
CAUTION:Risk of fire
Read the manual and follow the safetyinstructions before use.
Isolate from supply and wait 10 minutes before removingthis cover.
Ensure proper earth connection
Mount the inverter on a non-combustible surface.
A
V
FR-F 700
400V
!
!
MITSUBISHI
MITSUBISHI