Instruction manual

4. SERVO SYSTEM CPU DEVICES
4 44
(3) Manual pulse generator axis setting error information (D9185 to D9187)
................................................................................... Data from PCPU to SCPU
The corresponding axis setting resister (D714 to D719), the smoothing
magnification setting register (D752 to D754) and the manual pulse generator
1-pulse input magnification setting register (D720 to D751) are checked on the
leading edge of the manual pulse generator enable flag (M2051 to M2053), and
if an error is founded, it is stored into manual pulse generator axis setting error
corresponding.
0000 P1 P1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b4 b3 b2 b1 b0
D9185 0
b6
0
b5
P3 P2 P3 P20000
Axis16
D9186
D9187
Axis15 Axis14 Axis13 Axis12 Axis11 Axis10 Axis9 Axis8 Axis7 Axis6 Axis5 Axis4 Axis3 Axis2 Axis1
Axis32 Axis31 Axis30 Axis29 Axis28 Axis27 Axis26 Axis25 Axis24 Axis23 Axis22 Axis21 Axis20 Axis19 Axis18 Axis17
Store the smoothing magnification setting errors
of the manual pulse generators connected to P1
to P3 of A273EX.
0: Normal
1: Setting error
(Axis setting in each digit is other than 0 to 59)
Store the axis setting errors of the manual pulse
generators connected to P1 to P3 of A273EX.
0: Normal
1: Setting error
(Axis setting in each digit is other than 1 to 32)
All turn to 0.
Store the 1-pulse input magnification setting
errors of the axes.
0: Stopping
1: Operating
(Input magnification of each axis is other than
1 to 100)
(4) Error program No. (D9189) .............................Data from the PCPU to the SCPU
(a) When the servo program setting error flag (M9079) switches ON, the
erroneous servo program No. (0 to 4095) will be stored.
(b) If, once an error program number has been stored, an error occurs in
another servo program, the program number of the subprogram with the
new error is stored.