2. PROCEDURE FOR VIRTUAL MODE POSITIONING CONTROL
2 6
2.3 Differences Between The REAL and VIRTUAL Modes
Portions of the positioning data, positioning device, and servo programs, etc., used
in REAL mode operations are different when used in VIRTUAL mode operations.
The Motion Controller (SV13/22 REAL Mode) Programming Manual (type A273UH
CPU/A173UHCPU(-S1)) should be read after acquainting yourself with these
differences.
2.3.1 Positioning data
Positioning data used in the VIRTUAL mode is shown in Table 2.1 below.
Table 2.1 Positioning Data List
Item REAL Mode VIRTURL Mode Remarks
System settings
!!
Fixed parameters
!
System-of-units varies
according to the output
module used
Servo parameters
!!
Parameter block
!
Use of "PULSE"only
Zeroing data
!
JOG operation data
!
Limit switch output data
!
[
!
]:Used [ ]:Conditional use [
]:Not used
2.3.2 Positioning device
The operating ranges of VIRTUAL mode positioning devices are shown in Tables
2.2 below.
Table 2.2 Operating Range of Positioning Devices
Device Name REAL Mode VIRTURL Mode
Internal relays M2000 to M3839 M2000 to M5487
Special relays M9073 to M9079
Data registers D0 to D799 D0 to D1559
Special registers D9180 to D9199