Instruction manual
9. REAL & VIRTUAL MODE SWITCHING AND STOP/RESTART
9 − 4
(3) Synchronous encoder axis check
(a) The items shown in Table 9.3 below are checked to determine the
synchronous encoder status.
If an error is found, switching to the VIRTUAL mode will not occur. Error
causes can only be corrected by switching back to the REAL mode.
(b) When an error is found, the corresponding output module's error detection
signal (M2407+20n) will switch ON, and the error code will be stored in the
minor/major error code storage register.
Table 9.3 Synchronous Encoder Axis Checklist
Output Module Checked
Check
Sequence
Check Item
External
Synchronous
Encoder
Output Module
Normal
Condition
Abnormal
Condition
Not
connected
1
•
Is the synchronous encoder connected to
an A273EX/A172SENC unit?
!
Connected
Cable break