(c) The limit switch output data of the file register area are imported when the
real mode is switched to the virtual mode.
If the limit switch output data are normal, the limit switch output of the axis
set to the cam axis within-one-revolution current value mode is controlled on
the basis of those data.
(b) Executing "write of servo setting data to PC" from the peripheral device
writes the limit switch output data of the cam axis within-one-revolution
current value mode to block No. 12 (R328 to R1519) of the extended file
register area.
When some of multiple limit switch output data are to be written, transfer the
data written from the peripheral device to another device once, and write
them as required to the file register area. (Refer to Section 8.4.8)
REMARKS
1) As the memory cassette, the A3NMCA24 (192k bytes) or more is required.