Instruction manual
8. OUTPUT MODULES
8 − 44
8.4.7 Limit switch output data in current value within 1 cam revolution mode
Limit switch output data can be created by the user at IBM PC which have been
started up with the SW2SRX-GSV22PE software.
For details regarding the limit switch output data creation procedure, refer to the
SW2SRX-GSV22PE/SW0IX-CAMPE Operating Manual.
(1) Limit switch output data storage area
(a) The limit switch output data of the axis set to the cam axis within-one-
revolution current value mode (see Section 8.4.3 (11), (12)) are stored into
block No. 12 of the memory cassette's extended file register area. (The limit
switch output data not in the cam axis within-one-revolution current value
mode are stored into the internal memory.)
(b) The following is the format of the limit switch output data stored into block
No. 12 of the file register area.
R6
R0
R7
R71
R8
R72
R327
R1519
R328
R1520
to
to
to
to
See Section 8.4.5.
Block No. 10
Block No. 11
Block No. 12
Registration code
Cam data size
Cam data address table
Cam data
Limit switch output data
Registration code
Cam data
area
Limit output
data area
(1192 points)