8.4.6 Limit switch outputs in current value mode & real current value in 1 cam revolution mode
There are 2 types of limit switch outputs:
• Limit switch outputs in real current value mode.
• Limit switch outputs in real current value in 1 cam revolution mode.
(1) Limit switch outputs in real current value mode.
Limit switch outputs occur in accordance with the cam's real current value
(stroke).
[Cam]
Limit switch output
Stroke
(a) For two-way cam
The limit switch output pattern is identical for both directions.
Limit switch output example
Limit switch output
setting
(1 cam shaft revolution)
1 cycle
Stroke
Lower stroke
limit
0
0
32767
Cam pattern
Operation example
Stroke
Output value
(address)
t