Instruction manual

8. OUTPUT MODULES
8 39
(d) Cam data address table
Set the first address from where the cam data (max. 4 blocks) are stored.
Make setting after converting the first address of each cam No. into the
number of bytes starting from R0. Set "0" as the first address of the
unregistered cam No.
1) First block
R8
R9
R10
R70
R71
First block
Cam data address tabl
e
First address of cam No. 3
First address of cam No. 1
First address of cam No. 2
First address of cam No. 63
First address of cam No. 64
2) Second block
R1528
R1529
R1530
R1590
R1591
Second block
Cam data address table
First address of cam No. 101
First address of cam No. 102
First address of cam No. 103
First address of cam No. 163
First address of cam No. 164
3) Third block
R1856
R1857
R1858
R1918
R1919
Third block
Cam data address table
First address of cam No. 201
First address of cam No. 202
First address of cam No. 203
First address of cam No. 263
First address of cam No. 264
4) Fourth block
R2184
R2185
R2186
R2247
R2248
Fourth block
Cam data address table
First address of cam No. 301
First address of cam No. 302
First address of cam No. 303
First address of cam No. 363
First address of cam No. 364