Instruction manual
8. OUTPUT MODULES
8 − 26
8.4.3 Parameter list
The cam parameters are presented in Table 8.5 and item numbers 2 to 13 in the
table are described in (1) through (12) below.
For details on how to set the cam parameters refer to the Operating Manual for the
relevant motion controller.
Table 8.5 Parameter List
No. Setting Default Value Setting Range
1 Output shaft number 0 1 to 32
2 Number of pulses per cam shaft revolution 0 2147483647 PLS
3 Used cam No.
4 Cam No. setting device (1 word) (Nc)
Word device
5 Permissible droop pulse value 65535 PLS 1
to
65535 PLS
6 Unit setting mm mm inch PLS
7 Stroke setting device (2 words)
Word device
8 Limit switch output Not used Used/Not used
9 Torque control limit setting device (1 word)
−
−−
−
(300%)/word device
10 Comment None 32 characters
11 Stroke lower limit value storage device
−
−−
−
/ word device
12
Current value in one virtual axis revolution
storage device (main shaft side, 2 words)
−
−−
−
/ word device
13
Current value in one virtual axis revolution
storage device (auxiliary input shaft side, 2
words)
−
−−
−
/ word device
(1) Number of PULSES per cam shaft revolution (Nc)
(a) This is the setting for the number of PULSES required to rotate the cam
through one cycle.
(b) The setting for the number of PULSES per cam shaft revolution is
independent of the travel value per PULSE (setting in the fixed parameters).
(2) Used cam No.
This parameter does not need to be set.
Operation will be possible as long as a registered cam No. is set.
Number of PULSES per cam shaft revolution (Nc)