User`s guide
Table Of Contents
- E-Designer Reference Manual
- 1 Installation
- 2 General
- 3 Configuration with the Configuration Tool
- 3.1 Starting the Configuration Tool
- 3.2 Selecting Menu Language
- 3.3 Creating a Project
- 3.4 Saving a Project
- 3.5 Updating Drivers
- 3.6 Changing Project Properties
- 3.7 The Project Manager
- 3.8 The Block Manager
- 3.9 Showing Operator Panel around the Working Area
- 3.10 Configuration of Blocks
- 3.11 Using Text Blocks
- 3.12 Static Symbols
- 3.13 Changing I/Os
- 3.14 The I/O Browser
- 3.15 Changing BDTP Station
- 3.16 I/O Cross Reference
- 3.17 Other Managers/Editors
- 3.18 The File Menu
- 3.19 The Edit Menu
- 3.20 The View Menu
- 3.21 The Functions Menu
- 3.22 The Setup Menu
- 3.23 The Block Manager menu
- 3.24 The Object menu
- 3.25 The Layout Menu
- 3.26 The Project Menu
- 3.27 The Transfer Menu
- 3.28 The Window Menu
- 3.29 The Help Menu
- 4 Graphic Presentation and Maneuvering
- 5 Text-based Presentation for Printouts and Reports
- 6 Trends
- 7 Message Library
- 8 Alarm Management
- 9 Recipes
- 9.1 Calculation of Recipe Size
- 9.2 Recipe Properties and Recipe Directory
- 9.3 Creating a Recipe with the Operator Panel
- 9.4 Appending Recipes
- 9.5 Transferring Recipes to the Controller
- 9.6 Deleting Recipes
- 9.7 Using Recipes in a PC
- 9.8 Creating and Transferring Recipes with the Controller Program
- 9.9 Saving Individual Recipes on an External Memory Card in Runtime
- 10 Data Logger
- 11 Passwords
- 12 Printouts from the Operator Panel
- 13 Time Channels
- 14 Language Management
- 14.1 Unicode in the Operator Panel
- 14.2 Creating Additional Application Languages
- 14.3 Translating/Editing Texts in the Configuration Tool
- 14.4 Properties for the Application Language
- 14.5 Export
- 14.6 Import
- 14.7 Show Index
- 14.8 Cross Reference
- 14.9 Reuse Index
- 14.10 Font Templates
- 14.11 Unicode in E1012 and E1022
- 15 System Monitor
- 16 Index Addressing
- 17 Communication
- 18 Network Communication
- 19 Network Functions in the Operator Panel
- 20 LEDs
- 21 Function Keys
- 22 Macros
- 23 Project Transfer
- 24 Transfer of Controller Program and Parameters
- 25 Updating the Operator Panel

Graphic Presentation and Maneuvering
86 Mitsubishi Electric, MA00759F
Move
Two analog signals can be specified under the Move tab, the values of which
correspond to the X- and Y-coordinates (width and height) for the object.
Signal
Specify an analog signal.
Value from
Specify the analog signal’s minimum value.
Value to
Specify the analog signal’s maximum value.
From X-/Y-position
Specify the object’s X- and Y-coordinates, i.e. the pixel value on the display, when the
value in the parameter Value from = defined value.
To X-/Y-position
Specify the object’s X- and Y-coordinates, i.e. the pixel value on the display, when the
value in the parameter Value to = defined value.
Note:
If an unreasonable value is given, e.g. a value which means that the object cannot be
drawn on the display, the value will be ignored.
Note:
The property Visible must not be used together with the property Positions.