User`s guide
Table Of Contents
- E-Designer Reference Manual
- 1 Installation
- 2 General
- 3 Configuration with the Configuration Tool
- 3.1 Starting the Configuration Tool
- 3.2 Selecting Menu Language
- 3.3 Creating a Project
- 3.4 Saving a Project
- 3.5 Updating Drivers
- 3.6 Changing Project Properties
- 3.7 The Project Manager
- 3.8 The Block Manager
- 3.9 Showing Operator Panel around the Working Area
- 3.10 Configuration of Blocks
- 3.11 Using Text Blocks
- 3.12 Static Symbols
- 3.13 Changing I/Os
- 3.14 The I/O Browser
- 3.15 Changing BDTP Station
- 3.16 I/O Cross Reference
- 3.17 Other Managers/Editors
- 3.18 The File Menu
- 3.19 The Edit Menu
- 3.20 The View Menu
- 3.21 The Functions Menu
- 3.22 The Setup Menu
- 3.23 The Block Manager menu
- 3.24 The Object menu
- 3.25 The Layout Menu
- 3.26 The Project Menu
- 3.27 The Transfer Menu
- 3.28 The Window Menu
- 3.29 The Help Menu
- 4 Graphic Presentation and Maneuvering
- 5 Text-based Presentation for Printouts and Reports
- 6 Trends
- 7 Message Library
- 8 Alarm Management
- 9 Recipes
- 9.1 Calculation of Recipe Size
- 9.2 Recipe Properties and Recipe Directory
- 9.3 Creating a Recipe with the Operator Panel
- 9.4 Appending Recipes
- 9.5 Transferring Recipes to the Controller
- 9.6 Deleting Recipes
- 9.7 Using Recipes in a PC
- 9.8 Creating and Transferring Recipes with the Controller Program
- 9.9 Saving Individual Recipes on an External Memory Card in Runtime
- 10 Data Logger
- 11 Passwords
- 12 Printouts from the Operator Panel
- 13 Time Channels
- 14 Language Management
- 14.1 Unicode in the Operator Panel
- 14.2 Creating Additional Application Languages
- 14.3 Translating/Editing Texts in the Configuration Tool
- 14.4 Properties for the Application Language
- 14.5 Export
- 14.6 Import
- 14.7 Show Index
- 14.8 Cross Reference
- 14.9 Reuse Index
- 14.10 Font Templates
- 14.11 Unicode in E1012 and E1022
- 15 System Monitor
- 16 Index Addressing
- 17 Communication
- 18 Network Communication
- 19 Network Functions in the Operator Panel
- 20 LEDs
- 21 Function Keys
- 22 Macros
- 23 Project Transfer
- 24 Transfer of Controller Program and Parameters
- 25 Updating the Operator Panel

Configuration with the Configuration Tool
44 Mitsubishi Electric, MA00759F
Copying Graphics from Other Programs
Use the copy function in the other program (e.g. Paint). Right-click in the Library
and select Paste. Enter a name for the symbol.
The symbol is now saved in the symbol library with the given name.
With the copy and paste functions in the configuration tool it is possible to copy
graphics and symbols between blocks and between projects.
Symbol Manager for E1012 and E1022
E1012 and E1022 support black and white symbols only. The Symbol Manager for
E1012 and E1022 is activated by selecting View/Symbol Manager. In the Symbol
Manager there are functions for import and export of bitmap symbols. User-defined
symbols can also be created and deleted from the symbol library. The user-defined
symbols are shown in the symbols list. The pre-defined symbols are not shown since
they cannot be changed. The configuration tool is delivered with a number of differ-
ent symbols.
Export Symbols
Symbols in bmp format can be exported for use in other applications.
Note:
When a user-defined symbol is copied between projects, the actual symbol is only
copied if the symbol is not already used in the target project.