User`s guide
Table Of Contents
- E-Designer Reference Manual
- 1 Installation
- 2 General
- 3 Configuration with the Configuration Tool
- 3.1 Starting the Configuration Tool
- 3.2 Selecting Menu Language
- 3.3 Creating a Project
- 3.4 Saving a Project
- 3.5 Updating Drivers
- 3.6 Changing Project Properties
- 3.7 The Project Manager
- 3.8 The Block Manager
- 3.9 Showing Operator Panel around the Working Area
- 3.10 Configuration of Blocks
- 3.11 Using Text Blocks
- 3.12 Static Symbols
- 3.13 Changing I/Os
- 3.14 The I/O Browser
- 3.15 Changing BDTP Station
- 3.16 I/O Cross Reference
- 3.17 Other Managers/Editors
- 3.18 The File Menu
- 3.19 The Edit Menu
- 3.20 The View Menu
- 3.21 The Functions Menu
- 3.22 The Setup Menu
- 3.23 The Block Manager menu
- 3.24 The Object menu
- 3.25 The Layout Menu
- 3.26 The Project Menu
- 3.27 The Transfer Menu
- 3.28 The Window Menu
- 3.29 The Help Menu
- 4 Graphic Presentation and Maneuvering
- 5 Text-based Presentation for Printouts and Reports
- 6 Trends
- 7 Message Library
- 8 Alarm Management
- 9 Recipes
- 9.1 Calculation of Recipe Size
- 9.2 Recipe Properties and Recipe Directory
- 9.3 Creating a Recipe with the Operator Panel
- 9.4 Appending Recipes
- 9.5 Transferring Recipes to the Controller
- 9.6 Deleting Recipes
- 9.7 Using Recipes in a PC
- 9.8 Creating and Transferring Recipes with the Controller Program
- 9.9 Saving Individual Recipes on an External Memory Card in Runtime
- 10 Data Logger
- 11 Passwords
- 12 Printouts from the Operator Panel
- 13 Time Channels
- 14 Language Management
- 14.1 Unicode in the Operator Panel
- 14.2 Creating Additional Application Languages
- 14.3 Translating/Editing Texts in the Configuration Tool
- 14.4 Properties for the Application Language
- 14.5 Export
- 14.6 Import
- 14.7 Show Index
- 14.8 Cross Reference
- 14.9 Reuse Index
- 14.10 Font Templates
- 14.11 Unicode in E1012 and E1022
- 15 System Monitor
- 16 Index Addressing
- 17 Communication
- 18 Network Communication
- 19 Network Functions in the Operator Panel
- 20 LEDs
- 21 Function Keys
- 22 Macros
- 23 Project Transfer
- 24 Transfer of Controller Program and Parameters
- 25 Updating the Operator Panel

Configuration with the Configuration Tool
Mitsubishi Electric, MA00759F 39
Grouping Objects
After marking some objects on the working area, these can be grouped by selecting
Layout/Group. Grouped objects are treated as one object, the size of which can be
changed. The color and font can be changed individually for the objects in a grouped
object. When clicking on an object in a grouped object, the editing dialog for that
object is displayed.
Select Layout/Ungroup to ungroup a grouped object.
The Library
The Library contains a number of catalogues with different symbol objects. It is also
possible to define user-created catalogues by right-clicking on the Library and select-
ing Catalogue/New.
Grouped objects and symbols can be saved in the Library for reuse later, or in other
projects. Right-click on a grouped object or symbol on the working area, select Copy,
and then right-click in the Library and select Paste. A library object can be dragged
from the Library to the working area.
By right-clicking on the Library, it is possible customize the look of the Library.
Library catalogues can be closed by right-clicking on the catalogue and selecting
Catalogue/Close.
The Library can be hidden by selecting View/Toolbars/Library.
Symbol objects that are used in a project are saved in the project folder. These sym-
bols can also be selected from the Select Symbol dialog, described in chapter Static
Symbols.
Saving Symbols to the Library
Select one or several objects (grouped or ungrouped) on the working area with the
cursor. Right-click on the selection and select Copy. Right-click in the Library and
select Paste.