User`s guide

Table Of Contents
Transfer of Controller Program and Parameters
Mitsubishi Electric, MA00759F 311
24 Transfer of Controller Program and
Parameters
It is possible to transfer MELSEC FX (serial) controller program and parameters to
and from a USB Flash drive.
Other MELSEC drivers may also eventually support USB Flash drive transfer. Please
see the driver documentation to verify this.
Controller independent functions are built into the E1000-series software. Control-
ler specific functions can be found in the driver.
The USB memory stick must follow the standard for the USB mass storage device
class, i.e if the USB stick is delivered with a CD that contains drivers it will most like-
ly not work with the operator panels.
24.1 Transferring Controller Software to the
USB Flash Drive (Upload)
The controller program can be transferred at operator panel startup. This is enabled
by using the PLCU command, by selecting Setup/System Signals and typing the
command on the Commands line.
A USB Flash drive has to be connected to the operator panel at startup.
At operator panel startup, the drivers in the operator panel are checked to verify if
they support controller program upload/download. If so, and a USB Flash drive is
connected, a dialog is displayed, letting the user start or skip an upload. In a second
dialog, when having selected to start an upload, the user can enter the project name.
If no choice is made in 10 seconds after display of the first dialog, the operator panel
starts up without uploading controller software.