User`s guide
Table Of Contents
- E-Designer Reference Manual
- 1 Installation
- 2 General
- 3 Configuration with the Configuration Tool
- 3.1 Starting the Configuration Tool
- 3.2 Selecting Menu Language
- 3.3 Creating a Project
- 3.4 Saving a Project
- 3.5 Updating Drivers
- 3.6 Changing Project Properties
- 3.7 The Project Manager
- 3.8 The Block Manager
- 3.9 Showing Operator Panel around the Working Area
- 3.10 Configuration of Blocks
- 3.11 Using Text Blocks
- 3.12 Static Symbols
- 3.13 Changing I/Os
- 3.14 The I/O Browser
- 3.15 Changing BDTP Station
- 3.16 I/O Cross Reference
- 3.17 Other Managers/Editors
- 3.18 The File Menu
- 3.19 The Edit Menu
- 3.20 The View Menu
- 3.21 The Functions Menu
- 3.22 The Setup Menu
- 3.23 The Block Manager menu
- 3.24 The Object menu
- 3.25 The Layout Menu
- 3.26 The Project Menu
- 3.27 The Transfer Menu
- 3.28 The Window Menu
- 3.29 The Help Menu
- 4 Graphic Presentation and Maneuvering
- 5 Text-based Presentation for Printouts and Reports
- 6 Trends
- 7 Message Library
- 8 Alarm Management
- 9 Recipes
- 9.1 Calculation of Recipe Size
- 9.2 Recipe Properties and Recipe Directory
- 9.3 Creating a Recipe with the Operator Panel
- 9.4 Appending Recipes
- 9.5 Transferring Recipes to the Controller
- 9.6 Deleting Recipes
- 9.7 Using Recipes in a PC
- 9.8 Creating and Transferring Recipes with the Controller Program
- 9.9 Saving Individual Recipes on an External Memory Card in Runtime
- 10 Data Logger
- 11 Passwords
- 12 Printouts from the Operator Panel
- 13 Time Channels
- 14 Language Management
- 14.1 Unicode in the Operator Panel
- 14.2 Creating Additional Application Languages
- 14.3 Translating/Editing Texts in the Configuration Tool
- 14.4 Properties for the Application Language
- 14.5 Export
- 14.6 Import
- 14.7 Show Index
- 14.8 Cross Reference
- 14.9 Reuse Index
- 14.10 Font Templates
- 14.11 Unicode in E1012 and E1022
- 15 System Monitor
- 16 Index Addressing
- 17 Communication
- 18 Network Communication
- 19 Network Functions in the Operator Panel
- 20 LEDs
- 21 Function Keys
- 22 Macros
- 23 Project Transfer
- 24 Transfer of Controller Program and Parameters
- 25 Updating the Operator Panel

Macros
298 Mitsubishi Electric, MA00759F
Insert Event or Append Event
Click Insert Event or Append Event to display the following dialog. Each macro can
contain a maximum of eight different events (lines).
Parameter Description
I/O The signal to be linked to an event in the macro. In the field Event,
select which of the following events to be linked to the signal in the
macro:
Set - means that the digital signal is set to one and remains set to
one when the macro is activated from a key.
Dec analog - means that the analog signal will decrease the value by
the value indicated in the field Value when the macro is activated
from a key.
Reset - means that the digital signal is reset and remains reset when
the macro is activated from a key.
Set Analog - means that the analog signal is given the value by the
value indicated in the field Value when the macro is activated from
a key.
Toggle - means that the digital signal is set to one and reset
alternately when the macro is activated from a key.
Inc analog - means that the analog signal will increase the value by
the value indicated in the field Value when the macro is activated
from a key.
Jump to block Indicate the number of the name of the block to which a block jump
is to be made when the macro is activated from a key. A block jump
can only be the last event in a macro, since a block jump ends the
macro.