User`s guide

Table Of Contents
Network Functions in the Operator Panel
284 Mitsubishi Electric, MA00759F
Parameters for push_key.fn
Parameter Explanation Example
KEY Can assume the
values:
A-Z
0-9
ACK
LIST
MAIN
PREV
BACKSPACE
ENTER
UP
DOWN
LEFT
RIGHT
<FORM ACTION="http://<!--#exec cgi="/
get_ipaddr.fn"-->/push_key.fn" METHOD="POST">
Key = <SELECT NAME="Key">
<OPTION VALUE="ENTER">Enter
<OPTION VALUE="A">A
<OPTION VALUE="B">B
<OPTION VALUE="1">1
<OPTION VALUE="2">2
<OPTION VALUE="3">3
<OPTION VALUE="UP">Up
<OPTION VALUE="DOWN">Down
<OPTION VALUE="LEFT">Left
<OPTION VALUE="RIGHT">Right
<OPTION VALUE="PREV">Prev
</SELECT>
<INPUT TYPE="submit" VALUE="Submit"> <P>
</FORM>
F1-F22 Can assume the
values:
SET
RESET
TOGGLE
<FORM ACTION="http://<!--#exec cgi="/
get_ipaddr.fn"-->/push_key.fn" METHOD="POST">
<SELECT NAME="F2">
<OPTION VALUE="SET">Set
<OPTION VALUE="RESET">Reset
<OPTION VALUE="TOGGLE">Toggle
</SELECT>
<INPUT TYPE="submit" VALUE="Submit">
</FORM>