User`s guide

Table Of Contents
Network Communication
248 Mitsubishi Electric, MA00759F
Use remote address as gateway
Checked to let the remote node’s IP address be the gateway, i.e. the connection port
to another network. The default setting is OFF.
Request/provide local address
The request/providing of the remote node’s IP address. Should be 0.0.0.0 to use the
IP address provided from the remote node.
Note:
If the parameter Use remote address as gateway is not checked and a sub network is
used, the communication with the network will not function. This also means that
e-mail cannot be sent from the operator panel, but that it is possible to login to the
operator panel from the outside, e.g. with a FTP client or web browser.
Note:
When a panel acting as PPP client tries to send e-mail to a PPP server, and cannot get a
connection, the PPP client will try to connect 5 times with an interval of 2 minutes. Once
the connection is established, it will try to send the e-mail. If it does not success, it will
try to resend the e-mail 5 times with an interval of 50 seconds.
Note:
After downloading a project with PPP settings for the first time, it is recommended to
turn the power off the panel, and then turn it back on again, to avoid communication
problems that sometimes occur when using PPP.