User`s guide
Table Of Contents
- E-Designer Reference Manual
- 1 Installation
- 2 General
- 3 Configuration with the Configuration Tool
- 3.1 Starting the Configuration Tool
- 3.2 Selecting Menu Language
- 3.3 Creating a Project
- 3.4 Saving a Project
- 3.5 Updating Drivers
- 3.6 Changing Project Properties
- 3.7 The Project Manager
- 3.8 The Block Manager
- 3.9 Showing Operator Panel around the Working Area
- 3.10 Configuration of Blocks
- 3.11 Using Text Blocks
- 3.12 Static Symbols
- 3.13 Changing I/Os
- 3.14 The I/O Browser
- 3.15 Changing BDTP Station
- 3.16 I/O Cross Reference
- 3.17 Other Managers/Editors
- 3.18 The File Menu
- 3.19 The Edit Menu
- 3.20 The View Menu
- 3.21 The Functions Menu
- 3.22 The Setup Menu
- 3.23 The Block Manager menu
- 3.24 The Object menu
- 3.25 The Layout Menu
- 3.26 The Project Menu
- 3.27 The Transfer Menu
- 3.28 The Window Menu
- 3.29 The Help Menu
- 4 Graphic Presentation and Maneuvering
- 5 Text-based Presentation for Printouts and Reports
- 6 Trends
- 7 Message Library
- 8 Alarm Management
- 9 Recipes
- 9.1 Calculation of Recipe Size
- 9.2 Recipe Properties and Recipe Directory
- 9.3 Creating a Recipe with the Operator Panel
- 9.4 Appending Recipes
- 9.5 Transferring Recipes to the Controller
- 9.6 Deleting Recipes
- 9.7 Using Recipes in a PC
- 9.8 Creating and Transferring Recipes with the Controller Program
- 9.9 Saving Individual Recipes on an External Memory Card in Runtime
- 10 Data Logger
- 11 Passwords
- 12 Printouts from the Operator Panel
- 13 Time Channels
- 14 Language Management
- 14.1 Unicode in the Operator Panel
- 14.2 Creating Additional Application Languages
- 14.3 Translating/Editing Texts in the Configuration Tool
- 14.4 Properties for the Application Language
- 14.5 Export
- 14.6 Import
- 14.7 Show Index
- 14.8 Cross Reference
- 14.9 Reuse Index
- 14.10 Font Templates
- 14.11 Unicode in E1012 and E1022
- 15 System Monitor
- 16 Index Addressing
- 17 Communication
- 18 Network Communication
- 19 Network Functions in the Operator Panel
- 20 LEDs
- 21 Function Keys
- 22 Macros
- 23 Project Transfer
- 24 Transfer of Controller Program and Parameters
- 25 Updating the Operator Panel

Communication
226 Mitsubishi Electric, MA00759F
Properties in the Operator Panel and PC
The properties for Passthrough mode are made by double-clicking on the Peripherals
folder in the Project Manager. Drag the unit Transparent mode to the communica-
tion port where the PC is to be connected to the operator panel. Right-click on
Transparent mode and select Properties. Select Passthrough mode (if this is sup-
ported by the driver; see the manual for the driver). The properties for the port where
the PC is connected must correspond with the properties in the program in the PC
(the configuration tool for the controller).
Passthrough mode can be used both through serial and Ethernet communication.
Parameter Description
IP Properties Only used for communication in Transparent/Passthrough mode via
Ethernet. The Transparent mode unit must then be connected to a
TCP/IP connection.
Port number 6004, does not normally need to be changed. The
required protocol, TCP or UDP, is also selected here.
Controller
system
Only used for communication in Transparent/Passthrough mode via
Ethernet. The Transparent mode unit must then be connected to a
TCP/IP connection. Select if Transparent/Passthrough mode is to
be connected to Controller 1 or Controller 2.
Mode Select communication mode Transparent or Passthrough.
Timeout – Specify a time in seconds after which the operator panel
will return to RUN mode from the Passthrough mode if no
Passthrough communication has occurred.