User`s guide
Table Of Contents
- E-Designer Reference Manual
- 1 Installation
- 2 General
- 3 Configuration with the Configuration Tool
- 3.1 Starting the Configuration Tool
- 3.2 Selecting Menu Language
- 3.3 Creating a Project
- 3.4 Saving a Project
- 3.5 Updating Drivers
- 3.6 Changing Project Properties
- 3.7 The Project Manager
- 3.8 The Block Manager
- 3.9 Showing Operator Panel around the Working Area
- 3.10 Configuration of Blocks
- 3.11 Using Text Blocks
- 3.12 Static Symbols
- 3.13 Changing I/Os
- 3.14 The I/O Browser
- 3.15 Changing BDTP Station
- 3.16 I/O Cross Reference
- 3.17 Other Managers/Editors
- 3.18 The File Menu
- 3.19 The Edit Menu
- 3.20 The View Menu
- 3.21 The Functions Menu
- 3.22 The Setup Menu
- 3.23 The Block Manager menu
- 3.24 The Object menu
- 3.25 The Layout Menu
- 3.26 The Project Menu
- 3.27 The Transfer Menu
- 3.28 The Window Menu
- 3.29 The Help Menu
- 4 Graphic Presentation and Maneuvering
- 5 Text-based Presentation for Printouts and Reports
- 6 Trends
- 7 Message Library
- 8 Alarm Management
- 9 Recipes
- 9.1 Calculation of Recipe Size
- 9.2 Recipe Properties and Recipe Directory
- 9.3 Creating a Recipe with the Operator Panel
- 9.4 Appending Recipes
- 9.5 Transferring Recipes to the Controller
- 9.6 Deleting Recipes
- 9.7 Using Recipes in a PC
- 9.8 Creating and Transferring Recipes with the Controller Program
- 9.9 Saving Individual Recipes on an External Memory Card in Runtime
- 10 Data Logger
- 11 Passwords
- 12 Printouts from the Operator Panel
- 13 Time Channels
- 14 Language Management
- 14.1 Unicode in the Operator Panel
- 14.2 Creating Additional Application Languages
- 14.3 Translating/Editing Texts in the Configuration Tool
- 14.4 Properties for the Application Language
- 14.5 Export
- 14.6 Import
- 14.7 Show Index
- 14.8 Cross Reference
- 14.9 Reuse Index
- 14.10 Font Templates
- 14.11 Unicode in E1012 and E1022
- 15 System Monitor
- 16 Index Addressing
- 17 Communication
- 18 Network Communication
- 19 Network Functions in the Operator Panel
- 20 LEDs
- 21 Function Keys
- 22 Macros
- 23 Project Transfer
- 24 Transfer of Controller Program and Parameters
- 25 Updating the Operator Panel

Text-based Presentation for Printouts and Reports
130 Mitsubishi Electric, MA00759F
Scaling
The scaling function is available for several text objects.
The parameters Offset and Gain are used to change the scale of the controller value to
a value shown in accordance with the following equation.
Panel value = Offset+Gain*Register value
When the value for an object is changed from the operator panel, the scale is changed
to the value shown in accordance with the following equation.
RegisterValue = (PanelValue-Offset)/Gain
Scaling does not affect the defined maximum and minimum values, or the number
of decimal places.
Offset Gain Calculation
The function Offset Gain calculation is a tool to calculate the offset and gain
parameters. Specify the value of Offset and Gain under the General tab for the object
and click on Calculation. The following dialog is now shown.
Enter the range for the controller value and panel value. The correct values for the
parameters Offset and Gain are calculated.