Specifications

App - 40
Error code Description of error Corrective action
0x01808304
Insufficient size of the receive buffer
The receive data is greater than the
data provided by a system.
Complete a program and restart the DOS/V personal computer.
0x01808401
Control error
The communication control of the
COM port has failed.
Complete a program and restart the DOS/V personal computer.
0x01808403
Signal line designation error
Changing the communication
control of the COM port has failed.
Complete a program and restart the DOS/V personal computer.
0x01808404 Open not executed
Execute the open.
Complete a program and restart the DOS/V personal computer.
0x01808405
Communication parameter error
The combination of data and the
stop bit of property is unauthorized.
Review the data and the stop bit value of the property.
Reset it in the communication setting utility.
0x01808406
Baudrate value designation error
The baudrate of the property is
unauthorized.
Review the baudrate value of the property.
Reset it in the communication setting utility.
0x01808407
Data length error
The data bit value of the property is
unauthorized.
Review the data bit value of the property.
Reset it in the communication setting utility.
0x01808408
Parity designation error
The parity value of the property is
unauthorized.
Review the parity value of the property.
Reset it in the communication setting utility.
0x01808409
Stop bit designation error
The stop bit value of property is
unauthorized.
Review the stop bit value of the property.
Reset it in the communication setting utility.
0x0180840A
Communication control setting error
The control value of property is
unauthorized.
Review the control value of the property.
Reset it in the communication setting utility.
0x0180840B
Timeout error
Though a timeout time has passed,
the data cannot be received.
Review the timeout value of the property.
Reset it in the communication setting utility.
Review the systems such as the PLC CPU, module setting and
cable status.
Execute the Close, then execute the Open again
Complete a program and restart the DOS/V personal computer.
0x0180840C Connect error Complete a program and restart the DOS/V personal computer.
0x0180840D Double connect error Complete a program and restart the DOS/V personal computer.
0x0180840E
Attach failure
The attachment of Socket object has
failed.
Complete a program and restart the DOS/V personal computer.
0x0180840F
Signal line status acquisition failure
Acquiring the signal line status of the
COM port has failed.
Complete a program and restart the DOS/V personal computer.
0x01808410
CD signal line OFF
The CD signal of the communication
target is the OFF status.
Review the systems such as the PLC CPU, module setting and
cable status.
Complete a program and restart the DOS/V personal computer.
0x01808411 Password mismatch error Check the remote password of the property.
0x01808501
USB driver load error
The USB driver load has failed.
Complete a program and restart the DOS/V personal computer.
Reinstall the MX Component.