MITSUBISHI ELECTRIC E1032 Installation manual MA00816 2006-04 English
Foreword Installation manual for the E1000 series operator terminals Foreword The E1000 operator terminal is developed to satisfy the demands of humanmachine communication. Built-in functions such as displaying and controlling text, dynamic indication, time channels, alarm and recipe handling are included. The operator terminal work, for the most part, in an object-oriented way, making it easy to understand and use.
Table of Contents Table of Contents 1 Safety Precautions................................................................................. 1.1 UL Installation.................................................................................. 1.2 General ............................................................................................. 1.3 During Use ....................................................................................... 1.4 Service and Maintenance...................................
Table of Contents Mitsubishi Electric, MA00816
Safety Precautions 1 Safety Precautions Both the installer and the owner and/or operator of the operator terminal must read and understand this installation manual. 1.1 UL Installation Power, input and output (I/O) wiring must be in accordance with Class 1, Division 2 wiring methods (Article 501-4 (b) of the National Electric Code, NFPA 70) and in accordance with the authority having jurisdiction. 1.2 General – Only qualified personnel may install or operate the operator terminal.
Safety Precautions 1.4 Service and Maintenance – Only qualified personnel should carry out repairs. – The agreed warranty applies. – Before carrying out any cleaning or maintenance operations, disconnect the equipment from the electrical supply. – Clean the display and surrounding front cover with a soft cloth and mild detergent. – Replacing the battery incorrectly may result in explosion. Only use batteries recommended by the supplier. 1.
Installation 2 Installation 2.1 Space Requirements – Installation plate thickness: 1.5 - 7.5 mm (0.06 - 0.3 inch) – Space requirements when installing the operator terminal: 100 mm (4.0 inch) 187 mm (7.36 inch) 100 mm (4.0 inch) 50 mm (2.0 inch) 50 mm (2.0 inch) 100 mm (4.0 inch) 56.9 mm (2.24 inch) 202 mm (7.95 inch) Caution The openings on the enclosure are for air convection. Do not cover these openings. 2.2 Installation Process 1. Unpack and check the delivery.
Installation 3. Secure the operator terminal in position, using all the fastening holes and the provided brackets and screws: x4 0.5 - 1.0 Nm 4. Connect the cables in the specified order. A B Caution Ensure that the operator terminal and the controller system have the same electrical grounding (reference voltage level), otherwise errors in communication may occur. Use an M5 screw and a grounding conductor (as short as possible) with a cross-section of minimum 2.5 mm2.
Installation 2.2.1 Mode Switches All mode switches must be in OFF position during operator terminal use. The mode switches should not be touched unless by qualified personell. ON DIP 1 2 3 4 ON DIP 1 2 3 4 2.2.2 Connections to the Controller For information about the cables to be used when connecting the operator terminal to the controller, please refer to the help file for the driver in question. 2.2.
Installation 10 Mitsubishi Electric, MA00816
Technical Data 3 Technical Data Parameter E1032 Front panel, W x H x D 202 x 187 x 6 mm Mounting depth 56.9 mm (156.9 mm including clearance) Front panel seal IP 66 Rear panel seal IP 20 Keyboard material Membrane switch keyboard with metal domes. Overlay film of Autotex F157 * with print on reverse side. 1 million operations. Reverse side material Powder-coated aluminum Weight 0.
Technical Data 12 Mitsubishi Electric, MA00816
Chemical Resistance 4 Chemical Resistance 4.1 Metal Casing The frame and casing material is powder-coated aluminum. This powder paint withstands exposure of up to 24 hours duration to the following chemicals without visible change: Ammonia 25% Isopropyl alcohol Nitric acid 3% De-ionized water Tap water Chlorhydric acid 10% Butanol Cooling liquid 50% Washer fluid 33% Citric acid 10% Ligroin Sulphuric acid 20% Diesel Cooking oil Turpentine Ethanol 99.
Chemical Resistance 4.2.2 Autotex F157 Autotex F157 covers the membrane keyboard. Solvent Resistance Autotex F157 withstands exposure of more than 24 hours duration under DIN 42 115 Part 2 to the following chemicals without visible change: Potassium ferrocyanide/ ferricyanide Sodium hypchlorite <20% (bleach) 1.1.1.
Chemical Resistance Very slight discoloration was noted under critical viewing conditions with the following materials: Tomato juice Tomato ketchup Lemon juice Mustard Outdoor Use In common with all polyester based films, Autotex F157 is not suitable for use in conditions of long term exposure to direct sunlight.
Chemical Resistance 16 Mitsubishi Electric, MA00816
Operator Terminal Drawings 5 Operator Terminal Drawings 5.1 Communication Ports RS-232 RS-422 RS-485 RS-422/485 USB Ethernet Drawing No.
Operator Terminal Drawings 5.2 E1032 Outline Drawing No.
Operator Terminal Drawings 10,75 5.3 E1032 Text Strip 19,75 Text max 17,0x8,0 19,75 20,5 20,5 179 20,5 20,5 20,5 Text max 18,5x8,0 4,5 9 Drawing No.
MITSUBISHI ELECTRIC Mitsubishi Electric Automation, Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061, USA Mitsubishi Electric Europe B.V.