1) Cable connection diagram for a barcode reader manufactured by OMRON Corporation
The following shows connection cables that must be produced by the user.
Maximum cable length: confirm with the barcode reader manufacturer.
Barcode reader
Cable connection and signal direction
GOT
Signal
direction
Signal
name
Pin No. Pin No. Signal name
Internal
connection
FG 1
1 CD *1
SD(TXD) *2 2 2 RD(RXD)
RD(RXD) *2 3 3 SD(TXD)
RS(RTS) 4 4 ER(DTR)
CS(CTS) 5 5 SG
─ 6 6 DR(DSR)
─ 7 7 RS(RTS)
─ 8 8 CS(CTS)
SG 9 9 ─
*1: NC for GT11
*2: A dedicated cable, V509-W012 (cross cable), is used between the barcode reader and the cables mentioned
above. Even if the signal name for cable connection is SD-SD or RD-RD, the communication can be performed
with no problem.
3.2.3 System equipment (3)
Manufacturer
Wireless
barcode reader
Barcode reader
dedicated
communication
unit
Attached
cable
RS-232 cable
Nippon Systems
Development
Co.,Ltd.
AC-812-000-D1
PDC-812-400-00
+
PDC-812-300-D1
Included with a
barcode reader
Included with a
barcode reader
GT16
Not required with the
extended function OS,
Barcode [04.00.**] or later
GT15
Not required with the
extended function OS,
Barcode [03.00.00] or later
Produced by the user with
the extended function OS,
Barcode [02.04.**] or earlier
Refer to 1) below.
GT11
Not required
By using
Attached cable,
a barcode reader can be
connected to the GOT.