Specifications

[Issue No.] GOT-A-0010-AB [Page] 34/41
[Title] List of Valid Devices Applicable for GOT1000 Series
[Date of Issue] Ver. AB: December 2014 (First Edition: September 2005)
[Relevant Models] GOT1000 Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
(5) RS-232 cable connection diagram for an ICU-215 RFID controller manufactured by MARS TOHKEN
SOLUTION CO.LTD.
The following shows connection cables that must be produced by the user.
Maximum cable length: confirm with the RFID controller manufacturer.
RFID controller (ICU-215) Cable connection and signal direction GOT
Signal name Pin No.
Pin No. Signal name
/RXD 1
1 CD *1
/TXD 2 2 RD(RXD)
+5V 3 3 SD(TXD)
GND 4 4 DTR(ER)
GND 5 5 SG
6 DSR(DR)
7 RS(RTS)
8 CS(CTS)
9 5V *2
*1: NC for GT11
*2: Supply 5VDC to the RFID controller.
*For the cables between
and , refer to the manual created by MARS TECHNO SCIENCE Corp.
(6) RS-232 cable connection diagram for an ICU-215 RFID controller manufactured by PONGEE
INDUSTRIES CO., LTD.
The following shows connection cables that must be produced by the user.
Maximum cable length: confirm with the RFID controller manufacturer.
RFID controller Cable connection and signal direction GOT
Signal name Color
Pin No. Signal name
+12VDC Red
1 CD *1
Ground Black 2 RD(RXD)
TX+ White 3 SD(TXD)
Shield/Ground Yellow 4 DTR(ER)
5 SG
6 DSR(DR)
7 RS(RTS)
8 CS(CTS)
9
*1: NC for GT11
*For the cables between
and , refer to the manual created by PONGEE INDUSTRIES CO., LTD