Specifications

[Issue No.] GOT-A-0010-AB [Page] 19/41
[Title] List of Valid Devices Applicable for GOT1000 Series
[Date of Issue] Ver. AB: December 2014 (First Edition: September 2005)
[Relevant Models] GOT1000 Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
4) RS-232 cable connection diagram for a 2D code reader manufactured by MARS TOHKEN SOLUTION
CO.LTD.
The following shows connection cables that must be produced by the user.
Maximum cable length: confirm with the 2D code reader manufacturer.
2D code reader
Cable connection and signal direction
GOT
Signal name Pin No. Pin No. Signal name
── ── 1 CD *1
RXD /RD- 2 2 RD(RXD)
TXD /TD+ 3 3 SD(TXD)
── ── 4 DTR(ER)
GND 5 5 SG
── ── 6 DSR(DR)
── ── 7 RS(RTS)
RTS 11 8 CS(CTS)
CTS 12 9 ──
4.2.2 System equipment (2)
Manufacturer
2D code
reader
Power supply unit RS-232 cable
DENSO WAVE
INCORPORATED
GT10Q-SB
Included with a 2D code reader
(A Bluetooth adapter
(BA-10RKU) must be purchased
separately.)
CBBA-RS2000/9