System information
APPENDIX DPS PrintServer
APPENDIX PrintServer
Please, do not use front USB connection to connect Eye-One Device. Use any of free
system rear USB connections instead.
Eye-One device is used by DPS PrintServer for printer calibration and profiling. To do so,
several prints with colour patches have to be made. Then they have to be read with the
device in order to obtain the required measurements for the printer adjustment.
1.1.19 Eye-One device parts
These are the most important parts of the Eye-One device:
The device has an operation button on the left side. This button has to be pressed for reading
samples or for device calibration.
The white calibration tile is used only for the Eye-One calibration. The device must be placed
over it and the button has to be pressed when prompted in the software. Then, Eye-One
device will be calibrated and ready to use.
1.1.20 Eye-One operation
In this point it is explained how to read the printed patches with the Eye-One calibrator
device, either you are calibrating or profiling your system. It is very important understanding it
because this process will be assumed in the following chapter 5.3, where iQ management
wizard will be explained.
USB plugg
White calibration tile
Operation button