Specifications
Kiosk Kiosk Kernel Operator Manual
March 2006 - v2.2
CASE 1 CASE 2 CASE 3 CASE 4
SHUTDOWN
FROM OPERATOR
MENU
SHUTDOWN
FROM OPERATING
SYSTEM
SWITCH OFF
MAIN POWER SUPPLY
SWITCH OFF
UPS/Kiosk MAIN SWITCH
PROCEDURE 1 PROCEDURE 2 PROCEDURE 3 PROCEDURE 4
System (automatically)
1.- Closes Applications
2.- Saves Databases
3.- Closes Windows
4.- UPS waits for
configured time.
Operator (manually)
1.- Switches off main
power switch before the
configured time.
System (automatically)
1.- Kills applications
2.- Does not save
databases
3.- Closes the windows
Operator (manually)
1.- Switches off main
power
2.- UPS beeps
3.- UPS switches off
System (automatically)
1.- Waits for 2 minutes
2.- Closes applications
3.- Saves databases
4.- Closes the windows
5.- The UPS waits for the
configured time.
6.- UPS switches off
System (automatically)
1.- Switches off
This procedure may cause
a system malfunction!
Recommended Not recommended! Recommended Not recommended!
Case 3: this situation is the same case as a “Power Failure”:
• All the steps will be carried out by the system automatically.
• An incidence will be reported to the incidences database and sent by email (for ONLINE
Kiosks)
• If a request is being processed (e.g. printing), an error ticket will be printed and the remaining
copies will be kept by the system as Jobs Pending.