Inband Tones...
Suppress Tones [OFF]
This parameter allows inband tones to be suppressed on the DMI4. This is needed if the
DMI4 is going to be used for SMDI integration or for providing analog lines without any
integration.
Delay (ms) [300]
This is how long after the analog line goes off hook to the DMI4 that the DMI4 waits
before it plays the inband tones to the voicemail system.
Activation Code...
Serial Number 04022
This is the serial number of the card.
Activation Code [856-476-7401]
The activation code controls what features are enabled on the card. Do not enter new
numbers here unless CTL has issued them because this may prevent your card from
operating properly.
Reset To Factory Defaults...
Selecting this option returns all the settings to the factory default settings.
Diagnostics...
These are used for trouble shooting. Sometimes a new version of PBX software or a different format of
Caller-ID may cause values to change between the telephone being emulated and the PBX. These
options allow you to enable some troubleshooting of the line in conjunction with the PBXLink technical
support staff. The diagnostics are sent to the SMDI port along with the SMDI, once the menus have been
exited.
Port (1-4) [1]
This assigns the port number on which the diagnostics are active. Diagnostics can only work
on one port at a time.
Warnings [ON]
These are in plain-text (English) and it is recommended that they be left on to allow any
problems to be logged as soon as they arise. This feature would require that the application
software be able to log data from the SMDI port. Note that some application programs cannot
tolerate messages other than SMDI packets on the SMDI port. In this case, you must turn
Warnings off.
Trace [OFF]
This enables a low-level diagnostic display of activities on the PBX port of the card.
Raw [OFF]
This enables a hex output of everything traveling between the PBX and the card. This may
produce vary large amounts of data.
Time [OFF]
This parameter, if on, triggers the timestamp to be absolute time (from when the card was
started) instead of elapsed time between events.
Show Config...
This option displays values of all the parameters currently configured. This is a one time only
command, not a switch.
Show Signal Level...
This option shows the signal level being received on each of the ports. This is a one time only
command, not a switch.
Show Name Table...
(Norstar Only)
This option shows the table that is used to map names to extensions. The DMI4 builds this
table at start-up, at midnight, and any time that port 1 (digital) is removed and re-inserted. If
this table is missing, then integration will not work properly. This is a one time only
command, not a switch.
Refresh Name Table...
(Norstar Only)
This option forces the DMI4 to rebuild the name table. This is an immediate command, not a
switch.