Technical information

Troubleshooting and Repair
71
Checking the Number of T1
Trunk Cards
With LIGHTWARE 18 Release 2.0 or greater software, any peripheral
bay can have up to two T1 cards to a total maximum of eight T1 links
(with T1 Cards and T1/E1 modules) in the system.
Prior to LIGHTWARE 18 Release 2.0, the maximum number of T1 cards
was seven. The following table defines the maximum number (prior to
LIGHTWARE 18) of T1 Trunk cards in peripheral bays that can connect
to a Control Triple FIM Carrier or a Control Dual FIM Carrier in the
Control cabinet (cabinet 1).
Table 5: Maximum Number of T1 Trunk Cards
Prior to LIGHTWARE 18
Cab #
0 CFCII
or
0 CFCIII
1 CFCII
(ML)
1 CFCII
(EL)
2 CFCII
(EL)
1 CFCIII
(EL)
2 CFCIII
(EL)
1 CFCII
(10)
1
CFCIII
(11)
(EL)
1 2 1 1 0 1 0 0
2 2 2 2 2 2 2
3 1 1 1 1 1
4 1 1 1
5 1 1 1
6 1 1
7 1 1
max. 2 3 4 5 5 7 6