Technical information

Technician’s Handbook
56
Interpreting the Main Control Card
Power-Up Error Codes
The error codes listed in Table 3 may appear on the Main Control Card
numeric display during startup.
Note: 1. A normal running system may show other codes (card diagnostics or er-
rors). However, during start-up, only the codes in this table are possible.
Any other code shown during start-up indicates a faulty Main Control
Card.
2. Codes possible AFTER start-up include card diagnostics codes (last
card location tested - top number indicates bay number, bottom number
indicates card slot number). Maintenance logs give results of test, pass
or fail with cause.
Table 3: Main Control Card Error Code Summary
Error
Code
Likely Cause(s)
(blank)
Faulty power system.
Faulty Main Control Card.
0
Faulty Main Control Card.
E.
8
MOSS password was not purchased, a purchased option is
not enabled, an enabled option is not purchased, the system
password does not match, or the system id does not match.
Faulty System ID module.
C
Faulty Flash memory or Main Control Card - This code shows
for approximately 15 seconds during a proper power-up
sequence. If the code remains, then a problem exists.
-
-
Nothing - indicates successful software download. This
display may be immediately changed to display post-boot-up
codes (see note 1).