54
Flowchart 4: continued
D
See the troubleshooting procedure given for the set/dataset
in Troubleshoot Sets of the SX-200 EL/ML Technical
Documentation for other possible corrective actions.
Is the fault corrected ?
Check the cable and cable connections between the set
and the line card.
=> Try connecting the device directly to the cross-connect
field to verify against house wiring problems.
=> Try another port on the card to verify against backplane
problems.
Yes
No
Return faulty card
for repair.