Technical information
Introduction
9
Cabinet Configuration
The SX-200 EL system can have a maximum of seven bays.
The BCC III and the BRI card require LIGHTWARE 18 Release 2.0 or
greater. The BCC III, BRI card, PRI card, and Control Triple CIM card
require the SX-200 ELx cabinet.
In a main control cabinet: a FIM II or a CIM never goes on a
BCC III, a FIM II or a CIM can go on a PRI card.
For CLASS line functionality on the ONS/CLASS Line card, you must
install a DSP module (single) on the BCC III in the same SX-200 ELx
cabinet. The ONS Line functionality on the ONS/CLASS Line card is
backwards compatible with the older systems. The CLASS line
functionality is dependant on LIGHTWARE 18 Release 2.0 or greater.
For CLASS on the trunk side, you can install a LS/CLASS Trunk card
in the SX-200 ELx cabinet or SX-200 ML (FD) cabinet, slots 1-8. The
LS/CLASS Trunk card requires LIGHTWARE 19 Release 2.0. Prior to
LIGHTWARE 19 Release 2, the system required a LS/CLASS
module with the SPINE, a T1 (ANI/DNIS), or ISDN BRI, PRI, or
Network Gateway (CLID and CNID).
A DSP module (single) on the BCC III provides CLASS generators for
1-8 ONS/CLASS Line cards in the same bay. System wide, this DSP
module provides 16 conference bridges for Record a Call and 16
DTMF receivers.
MOSS System Option 96, Number of Links (0-8) monitors the number
of T1 links from T1/E1 modules that the system will support. This
count includes T1 links from the T1/E1 modules on the PRI cards and
BCC III cards. This count does not include T1 links from the T1 cards.
LIGHTWARE 18 Release 2.0 or greater supports a maximum of 8 T1
links (includes T1 links from T1/E1 modules and T1 cards) in the
SX-200 EL system. Any bay can support up to two T1 links to a total
of eight in the system.
LIGHTWARE 17 supports one digital bay with two T1 trunk cards and
the other digital bays with one T1 trunk card to total a max of 7.
Remember to program CDE Form 04, Options 71 and 72, to
match the configuration.