Technical information

Technician’s Handbook
192
Initial Power-up Procedure
(SX-200 EL/ML)
When the system is first installed, use the following procedure to enter
the database into the system using CDE.
1. Verify that the options identified on the MOSS have been purchased.
2. Ensure that the System ID module is installed.
3. Insert the flash memory card into the slot on the Main Control Card
(make sure the toggle switch on the edge opposite the connector
edge of the flash memory card has the Write Protect disabled).
4. Turn the power supply ON, and wait for the power-up sequence to
complete.
5. Press RETURN four times; the terminal display returns:
1 - VT100™ COMPATIBLE
2 - TTY TYPE
3 - IBM PC
SELECT A TERMINAL TYPE :
6. Select the terminal type by entering “1”. The display returns:
1 - MAINTENANCE
2 - CDE
6 - QUIT
SELECT AN APPLICATION ( OR QUIT TO START OVER ) :
If powering up a single cabinet system, immediately revise
Alarm Thresholds to eliminate PCM alarms (software defaults
to a multi-cabinet system).
Users must purchase the option and its associated password
through their usual ordering channels prior to attempting to
install or implement the option.
Refer to the SX-200 EL/MLTechnical Documentation, Installation
Procedures.