Technical information
Technician’s Handbook
188
Slot 11 embedded CIM #2 interfaces to Bay 5.
Slot 11 embedded CIM #3 interfaces to Bay 7.
Configuration Rules for the PRI Card
The main control cabinet supports one PRI card in Slot 10 or 11.
The PRI card in slot 10 is Bay 2.
The PRI card in slot 11 is Bay 4.
The FIM II or CIM on the PRI card in slot 10 interfaces to Bay 3.
The FIM II or CIM on the PRI card in slot 11 interfaces to Bay 5.
T1 Trunk Rules for SX-200 RM Cabinets
LIGHTWARE 18 and greater software supports up to two T1 links
(includes T1 links from T1/E1 modules and T1 cards) in any bay with
a maximum of eight T1 links in the system.
The MOSS System Option 96, Number of Links (0-8) monitors how
many T1 links (from T1/E1 modules) that the system will support. This
count includes T1 links from the T1/E1 modules on the PRI cards and
BCC III cards. The count does not include T1 links from the T1 cards.
PIC slot 5 must be left vacant when a T1 card is installed in slot 10 or
when Link 1 from a T1/E1 module on a BCC III is programmed.
PIC slot 6 must be left vacant when a T1 card is installed
in slot 11 or when Link 2 from a T1/E1 module on a BCC III is
programmed.
.
A FIM II module can take the place of a CIM circuit on the
Control Triple CIM Card. Setting switch 1, 2, or 3 closed on the
S1 switch defines which specific CIM circuit that the FIM II
replaces. The FIM II will then interface to the bay that was
assigned to that CIM circuit.
Do NOT insert T1 trunk cards into slots 5 or 6.