Technical information

Installation
187
Configuration Rules for the Control Triple FIM Carrier Card
The Control Triple FIM Carrier Card can only be installed in a
SX-200 EL system.
Slot 10 first on-board FIM interfaces to first peripheral
cabinet (Bay 2)
Slot 10 second on-board FIM interfaces to second peripheral cabinet
(Bay 3)
Slot 10 add-on FIM interfaces to fifth peripheral cabinet (Bay 6)
Slot 11 first on-board FIM interfaces to third peripheral
cabinet (Bay 4)
Slot 11 second on-board FIM interfaces to fourth peripheral
cabinet (Bay 5)
Slot 11 add-on FIM interfaces to sixth peripheral cabinet (Bay 7)
Configuration Rules for the Control Triple CIM Card
The Control Triple CIM card has a S1 switch that sets the card as a triple
interface card (switch 4 closed) or a double interface card (switch 4
opened).
If the S1 switch on the Control Triple CIM card is set to take two circuits
(emulates the control dual carrier card), the following positions are hard
coded in the software:
Slot 10 embedded CIM #1 interfaces to Bay 2.
Slot 10 embedded CIM #2 interfaces to Bay 3.
Slot 11 embedded CIM #1 interfaces to Bay 4.
Slot 11 embedded CIM #2 interfaces to Bay 5.
If the S1 switch on the Control Triple CIM card is set to take three circuits
(emulates the control triple carrier card), the following positions are hard
coded in the software:
Slot 10 embedded CIM #1 interfaces to Bay 2.
Slot 10 embedded CIM #2 interfaces to Bay 3 .
Slot 10 embedded CIM #3 interfaces to Bay 6.
Slot 11 embedded CIM #1 interfaces to Bay 4.