Introduction
5
Configurations
SX-200 EL System
The SX-200 EL system contains one control cabinet with the following
components:
A Main Control Card IIIEL (MCC IIIEL) or Main Control Card IIIELx
(MCC IIIELx) in slot 12
One Bay Control Card (BCC II or BCC III) in slot 9
One Bay Power Supply
Up to two Control Dual FIM Carriers (CFCII), Control Triple FIM
Carriers (CFCIII), or Control Triple CIM (CTC) cards in slots
10 and 11
Up to 1 PRI card in unused slots 10 or 11
Up to two T1 Trunk cards in unused slots 10 or 11
Up to eight Peripheral Interface Cards in slots 1 to 8.
The SX-200 EL Control cabinet with an MCC IIIEL card or MCC IIIELx
card supports up to six peripheral bays. The MCC IIIELx card can also
support up to two SX-200 IP Nodes. The peripheral bays can be SX-200
EL peripheral cabinets, SX-200 LIGHT peripheral cabinets, SPINE Bays,
ISDN Network Gateways, or PRI cards.
A seven cabinet system will provide a non-blocking system if a
MCC IIIELx card in the SX-200 ELx cabinet (PN 9109-600-002-NA) is
installed with each of the following combinations:
Two CFCIII cards with LIGHTWARE 17 Release 3.1 or greater
Two CTC cards set to the triple interface setting with LIGHTWARE 18
Release 2.0 or greater.
The SX-200 IP Node requires LIGHTWARE 19, Release 3.0