Technical information

Programming
145
3. Form 12, Dataset Assignment
Assign the Circuit Descriptor COS, COR, and Tenant.
Ensure that the DTE profile is blank.
4. Form 04, System Options: program the following:
5. Form 03, Class of Service Define: program the following table:
If you make changes to a Dataset’s Circuit Descriptor after it is
powered-up you must power down then power up the Dataset
for the changes to take effect.
System Options / Timers Status
04 Message Waiting and Message Register Clear Print ENABLE
11 Automatic Wake-Up ENABLE
13 Automatic Wake-Up Print ENABLE
32 Outgoing Call Restriction ENABLE
108 Property Management System ENABLE
27 Room Status Audit DISABLE
33 Room Status DISABLE
34 Auto Room Status Conversion / Wake Up Print DISABLE
Device COS Option Status
Attendant
Consoles
101 Attendant Outgoing Restriction / Room Status Set Up ENABLE
105 Attendant Guest Room Key ENABLE
Room
Telephones
202 Alarm Call ENABLE
220 Do Not Disturb ENABLE
232 Message Waiting SETUP Lamp ENABLE
703 Message Register Applies ENABLE
239 Priority Dial 0 (optional - see step 6) ENABLE
244 Room Status Applies DISABLE
608 SUPERSET Status Display DISABLE