Technical information

Technician’s Handbook
142
Programming Symbol MiNET Wireless
Phones (Optional)
A site survey by Symbol Technologies followed by the installation and
configuration of Air Access Points (also by Symbol) precedes
programming of the phones.
1. Complete Programming on the SX-200.
2. Install the Symbol NetVision MiNET phone administrator tool on a
Windows NT or Windows 2000 PC (see below).
3. Upgrade the Symbol phone firmware to use the MiNET protocol.
Refer to the Symbol NVP II MiNET Update Procedure document
(Symbol MiNET.pdf) found on the SX-200 IP Node software CD.
The instructions in the Update Procedure document refer to a
configuration text file. Use the Minet_protocol.txt file provided on the
SX-200 IP Node software CD. The file is located in the folder
3rd Party/Wireless/Administration_Tool/.
4. Configure the wireless phones using the Symbol NetVision MiNET
Phone Administrator Tool.
Install Symbol NetVision MiNET Phone
Administrator Tool
The tool is found on the SX-200 IP Node software CD and must be
installed on a PC that is running Windows NT or Windows 2000.
To install the tool:
1. Insert the software CD into the CD-ROM drive.
2. Click \3rd_Party\Wireless\Administration_Tool \MiNET<xxx>.exe.
3. Click Unzip to place files in C:\temp\symbol.
4. Click Close.
5. Open the C:\temp\symbol folder.
6. Click setup.exe.
7. Follow the instructions in the install wizard.