CDE Programming for the SX-200 IP Node
1. If you are using IP Trunking, access CDE Form 04, System Options
and enable the following options:
Option 86: Enable PRI Q.sig
Option 115: Set the maximum number of IP Trunks to a value
from 1 to 60. Note that each IP phone to IP Trunk call consumes
two channels per call, which means up to 30 such calls are
supported per IP Node. For more information about each type of
call and the number of channels consumed, see the Maximum IP
Trunks description for CDE Form 04 in the SX-200 Technical
Documentation.
Option 100: Enter the MOSS password
Option 48: Set to 1 to 2 seconds.
Options 71 and 72: ensure these settings match the card types
installed.
2. Form 01 - System Configuration
Assign an IP Node to a bay.
Assign IP Line Cards to slots 1 to 5 of any bay that is assigned to
an IP Node.
If you are using IP Trunking, assign IP Trunk Cards to slot 6 of
any bay that is assigned to an IP Node.
3. Form 48 - IP Nodes (optional - used for IP trunking only)
For each local IP Node, specify an IP Node number and bay
number.
For each remote IP Node, specify an IP Node number, IP
Address and maximum number of calls.
If you plan to route calls to remote IP Nodes or 3300 ICPs, enter
the IP Addresses of these nodes and specify the maximum
number of calls.
4. Form 03 - COS Define
Enable options 801, 802 and 811.