Technical information

Programming
137
Programming an SX-200 IP Node
Initializing the SX-200 IP Node
1. Ensure the SX-200 IP Node is not connected to a power source.
2. Disconnect the the Ethernet cable from the Ethernet port on the
SX-200 IP Node.
3. Using a serial cable, connect a PC to the Maintenance Port on the IP
Node.
4. Launch a data communication application, such as Hyperterminal on
the PC.
5. Set the parameters: 9600, 8, N, 1, None.
6. Plug in the SX-200 IP Node to a power source.
7. At the “Press any key to stop and auto-boot” prompt, press any key.
8. At the [VxWorks Boot] prompt, type ‘c’ and press Enter.
9. Press Enter to type data in the following fields:
inet on ethernet (e): IP address of the SX-200 IP Node
gateway inet (g): IP address of the WAN gateway or router
10. Press Enter until the [VxWorks Boot] prompt appears.
11. Type ‘@’ and press Enter.
12. After the Critical Alarm LED turns off, reconnect the Ethernet cable.
13. From VxWorks “Ping” all the destination IP Nodes that will be on IP
Trunks. For example:
->ping “192.168.8.2”. The VxWorks Ping command requires quotes.