Technical information

Programming
127
Programming a range of Non Dial-in Trunks
The RANGE PRGRM softkey allows block programming of trunks on the
same card. You must program the first trunk in the range and then press
RANGE PRGM to copy the values to the range of trunks that you specify.
The following fields are copied from the first trunk in the range:
COS, TEN, DAY, N1, N2, CDN
The TK NAME and COMMENTS fields are left blank.
The trunk numbers are assigned in sequence, beginning with the first
trunk in the range. If there are trunks that are already programmed within
that range, those trunks are skipped. The trunk number sequence is
incremented each time a trunk is skipped. If the trunk number is
incremented to a value that is already used, the sequence continues to
increment until a free number is found. The trunk numbers restart at 1 if
necessary. An error message is displayed if there are no more free trunk
numbers.
Note: BRI trunks are not supported.
To program a range of trunks:
1. Program the first trunk in the range. Enter values for the COS, TEN,
DAY, N1, N2, CDN fields.
2. Press RANGE PRGRM.
The system displays: FROM BAY: SLOT: CIRCUIT:.
3. Enter valid Bay, Slot and Circuit numbers for the first trunk and press
the ENTER softkey.
The system displays: TO BAY: SLOT: CIRCUIT:.
4. Enter valid Bay, Slot and Circuit numbers for the last trunk and press
the ENTER softkey.
The system copies the values from the first trunk to all the trunks
specified in the range.