Technical information

Programming
113
Programming Stations/Sets
Automatically
The AUTO PROGRAM function in CDE Form 09, Desktop Device
Assignments, checks for unprogrammed circuits on all installed and
programmed ONS cards, OPS cards, and DNIC cards. Cards that are
installed in Spines are not supported.
All unprogrammed circuits are automatically programmed as follows:
Extension numbers are automatically assigned according to a Bay,
Slot, Circuit address format "BSCC", where
B is the Bay number (1-7)
S is the slot number (1-8)
CC is the cct number (01-12).
For example, extension number 2608 is assigned to a phone
connected to Bay 2, Slot 6, Circuit 08.
Other parameters for ONS and OPS devices are assigned as
COS = 1
COR = 1
Tenant = 1
Other parameters for DNIC sets are assigned as
COS = 2
COR = 4 for all set types except SUPERSET 430 and
SUPERSET 4150
COR = 5 for the SUPERSET 430 and SUPERSET 4150
Tenant = 1
Note: Before an extension number can be automatically assigned, a DNIC
set or DMP must be physically connected to the circuit. If no set or con-
sole is detected on a circuit, that circuit is skipped and no extension
number is assigned.