Technical information

Troubleshooting and Repair
105
Note: Failure of any test line command sequence necessitates using more
sophisticated maintenance tools.
Table 17: Test Line Status Indicator Codes
Code Meaning
PA The attempted operation was successful (pass).
FA The attempted operation was unsuccessful (fail).
(blank) System is waiting for command input.
II Test was inconclusive.
E5
Invalid command or device location entered; only those com-
mands in Table 16 are acceptable.
bb Device was busy. Try again later.
7E
An invalid physical location number was entered. Enter bay
number (01), slot number (04), and circuit number (06).
FF
Unknown error. Attempt operation again - ensure correct use
of command codes (see Table 16).
1E
Error in acquiring the software ID of the test line. Attempt oper-
ation again - ensure correct use of command codes (see Table
16). If necessary, use maintenance terminal or console.
2E
Possible software error. Attempt operation again - ensure cor-
rect use of command codes (see Table 16). Use maintenance