Technical information

Troubleshooting and Repair
97
SX-200 IP Node Troubleshooting
Table 15: SX-200 IP Node Troubleshooting Table
Indication Possible Causes Action
WARNING: SX200
Main control not con-
nected or IP Node
not supported
Defective Ethernet
cables
Replace the Ethernet
Crossover cable and
CIM cable.
The Control Triple
CIM card is pro-
grammed as a Dual
CIM card.
Reprogram the Triple
CIM Card.
The CIM cable is con-
nected to the wrong
port on the SX-200 IP
Node
Check the hardware
connections.
The IP Bay is not pro-
grammed in CDE
Form 01
Program the IP Bay in
CDE Form 01.
Programming in CDE
Form 04 and CDE
Form 47 is not correct
Check the program-
ming in CDE Form 04
and CDE Form 47.
(Sheet 1 of 6)