Specifications
General Information Guide
- 14 -
Environment for DSU and Peripheral Units
Storage Environment for DSU and Peripheral units
Condition Specification
Temperature -40º to 150ºF (-40º to 66ºC)
Humidity 5-95% Relative Humidity, non-condensing
Vibration 0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
Mechanical Stress
One 20.3 cm (8 inch) drop, each edge and corner adjacent to the rest
face
Operational Environment for DSU and Peripheral units
Condition Specification
Temperature 32º to 122ºF (0º to 50ºC)
Humidity 5-95% Relative Humidity, non-condensing
Maximum Heat Dissipation -
fully loaded (see Note)
Peripheral Cabinet 724 BTUs per hour
DSU Cabinet 266 BTUs per hour
Air Flow 150 cubic feet per minute at maximum output of the fans
Acoustic Emissions Maximum 50 dBA continuous, 75 dB intermittent (<10% duty cycle)
Note: Conversion factors: 1 watt is equal to 3.412 BTUs per hour, 1 ton of refrigeration is equal to
12,000 BTUs per hour or 3.516 Kilowatts.
Additional information can be found in the 3300 ICP Hardware User Guide.
Dimensions and Weights
Component Height Width Depth Weight
3300 Controller 2.75 in.
(7 cm)
19.0 in.
(48.3 cm)
15.5 in.
(39.4 cm)
16.19lbs
(7.35kg)
3300 Universal NSU 1.75 in.
(4.45 cm)
19 in.
(48.3 cm)
15.5 in.
(39.4 cm)
9.25lb
(4.2kg)
3300 R2 NSU 1.75 in.
(4.45 cm)
19 in.
(48.3 cm)
15.5 in.
(39.4 cm)
9.63lb
(4.37kg)
3300 BRI NSU 1.75 in.
(4.45 cm)
19 in.
(48.3 cm)
15.5 in.
(39.4 cm)
9.57lb
(4.34kg)
3300 Universal ASU 1.75 in.
(4.45 cm)
19 in.
(48.3 cm)
15.5 in.
(39.4 cm)
10.54lb
(4.79kg)
3300 ASU 1.75 in.
(4.45 cm)
19 in
(48.3 cm)
15.5 in
(39.4 cm)
9.98lb
(4.53 kg)
Digital Service Unit 19 in.
(48.3 cm)
9 in.
(22.9 cm)
16.5 in.
(42 cm)
40lb
(18 kg)
Peripheral Cabinet 19 in.
(48.3 cm)
18 in.
(48.3 cm)
16.5 in.
(42 cm)
95lb
(43.2 kg)