Specifications

General Information Guide
- 9 -
Migration
The 3300 ICP offers the ability to migrate from an existing SX-2000 MICRO LIGHT, SX-2000 LIGHT,
or 3200 ICP. The database is converted and restored onto the 3300 ICP by using the Mitel Networks
3300 Configuration Tool.
Mitel Networks SX-2000 MICRO LIGHT
By installing a triple FIM card in the SX-2000 MICRO LIGHT cabinet, you can connect it to the 3300
ICP by using multi-mode fiber. As a result, you can use the existing peripheral and digital trunk cards
within the cabinet. Any additional cabinets can also be connected by using FIMs.
Mitel Networks SX-2000 LIGHT
The SX-2000 LIGHT Digital Services Unit (DSU) cabinet provides digital trunk capability, and the
peripheral cabinet provides connectivity for analog trunks, analog telephones, and Mitel Networks
DNI devices. Both cabinet types can be connected to the 3300 Controller by using multi-mode fiber
connections.
The DSU cabinet supports BRI, PRI, T1/D4, MSDN/DPNSS, and DASS II trunks.
The peripheral cabinet supports the following analog trunks:
Analog CO trunks
E&M trunks
Direct Inward Dial and Tie Trunks.
It also supports the following DNI telephones and devices:
SUPERSET™ 401
SUPERSET 401+
SUPERSET 410
SUPERSET 420
SUPERSET 430
SUPERSET 4001
SUPERSET 4015
SUPERSET 4025
SUPERSET 4125
SUPERSET 4150
SUPERCONSOLE 1000
®
Mitel Networks Analog Interface Module.
For additional information, refer to SX-2000 technical documentation.