Specifications
Appendix A: Private Networking
T1/PRI and E1/PRI Programming
Mitel
®
5000 Installation Manual – Issue 3.0, October 2008 Page A-9
4. T1/PRI networking only. Set the Line Build-Out for both nodes. In the Communications
Server folder, locate the module configured in each node (for networking) and set the
following:
a. Click on the module configured for T1/PRI or E1/PRI.
b. Click on the Line Build-Out value and select the option from the list.
5. Double-click the remote node extension (System/Devices and Feature Codes/Nodes)
you created in step 1 on page A-7.
6. Perform the following on each node that will network to the other.
a. Under the Node/Trunk IP Connection Groups folder, right-click in the empty area and
select Add to Node Trunk/IP Connection Groups List.
b. Select Node IP Connection Group from the list. Click Next.
c. Click the P8000 extension. Click Add Items. Click Finish.
d. Double-click the Off-Node IP Connection Group extension you created in step 6c
(P8000).