Specifications

Chapter 6: Programming
Procedure
Mitel
®
5000 Installation Manual – Issue 3.0, October 2008 Page 6-151
Procedure
This procedure provides information on how to attach an external voice processing system to
the Mitel CS-5200/5400/5600 when using the DEI. For information about installing and setting
up the available external voice processing systems, refer to the documentation provided with
those units (see above in Overview).
For sample diagrams of the assembled voice processing computer, refer to the Installation
chapter. An 8.5 ft (2.5 m) cable is available, part no. 813.1806. Or, if necessary, contact the
Mitel CommSource
®
division for information on purchasing longer cable lengths.
To attach an external voice processing system:
1. From a DB Programming session, do the following:
Perform a database backup.
Disable Basic Voice Mail. Select Operations – Voice Processing Operations –
Disable Basic Voice Mail.
2. If this is a new installation, proceed to step 3.
If this is an existing installation,
Back up Basic Voice Mail. See “Saving the System and Voice Processor
Databases” on page 5-91.
Disable Basic Voice Mail. See “Enable Basic Voice Mail or Disable Basic Voice
Mail” on page 5-93.
3. Install the external voice processing PC in the rack under the DEI chassis. If the voice
processing PC cannot be placed in the rack, place it in proximity to the rack (distance is
limited by the connection cable provided). If necessary, follow the instructions included
with the voice processing PC you purchased.
4. Attach the Ethernet cables from both chassis to the LAN. Use a switch if necessary. Do
not use a hub. For more information, refer to the Installation chapter.
5. Attach the cable, part no. 813.1806, from the external voice processing PC to the DEI
chassis.
6. Plug the UPS into an isolated, dedicated single-phase commercial power source.
7. Attach and plug in the power cord for the Mitel CS-5200/5400/5600, DEI(s), and voice
processing PC chassis. Check that all systems are powered up.
8. Program the external voice processing system to connect to the Mitel CS-5200/5400/
5600 system. Refer to the external voice processing system manual for information.
Use the Administration Web Session pages to verify that Basic Voice Mail is disabled. The
Administrative Web Session login/password is it5k/itpassw.
NOTICE
External Voice Mail Inoperability. If you have an existing external voice processing
system (VPU or EM), you cannot use the existing cable to connect the external voice
processing system to the Mitel CS-5200/5400/5600 Base Server. You must use cable
part no. 813.1806.