Specifications
Chapter 3: Product Description
Data Port Modules
Mitel
®
5000 Installation Manual – Issue 3.0, October 2008 Page 3-11
Data Port Modules
The Personal Computer Data Port Module (PCDPM) and Modem Data Port Module (MDPM)
are connected to appropriate digital endpoints to provide hard-wire paths necessary to connect
Digital Station Select (DSS)/Busy Lamp Field (BLF) units. Contrary to their names, however,
neither device supports serial data.
Personal Computer Data Port Module
The PCDPM can be installed on Standard, Associate, Executive, and Professional Display
endpoints or on Models 8520 or 8560 endpoints to gain Off-Hook Voice Announce (OVHA)
receive capability or to install an optional Modem Data Port Module (MDPM).
Modem Data Port Module
The optional Modem Data Port Module (MDPM) can be installed on Standard Display, Executive
Display, Model 8520, or Model 8560 endpoints for attaching a modem-equipped data device or
a single line endpoint. The MDPM requires a PCDPM.
The Model 8416 Mini-DSS connects to Model 8520 or Model 8560 digital endpoints without
PCDPM and MDPM devices. The only programming required for the Mini-DSS is a keymap,
which is explained in detail in the Inter-Tel 5000 Features and Programming Guide (part no.
580.8006).
Administrative Web Session
The Administrative Web Session (AWS) shows whether a Mitel 5000 system is equipped with
DEIs and whether DEM-16 ports are enabled.
Mitel CS-5600 systems provide two AWS interfaces—one for the Base Server and the other for
the Processing Server (PS-1).
Trunks and Endpoints
The Mitel 5000 platform supports the following trunks, spans, gateways, and endpoints:
• Central Office (CO) [Local Exchange] Trunks: Up to 12 loop start [local exchange]
trunks can be installed in increments of four trunks per LSM-4 module. In addition, two
loop start trunks can be installed in the RJ-14 port built in on the Inter-Tel 5000 Base
Server.
• Spans: Up to six T1, T1/PRI, or E1/PRI spans can be installed in the Inter-Tel CS-5200/
5400/5600 Base Server.
o T1: In Database (DB) Programming each of the 24 channels of a channelized T1 span
can be enabled as any of the following types of channels or circuits:
– Loop Start
– Ground Start
– DID (Direct Inward Dial)/[in Europe, DDI (Direct Dial Inward)]
– E&M (Ear and Mouth/2-way)
– OPX (Off Premises Ex
tension)
NOTE
The PCDPM supports audio only when used in conjunction with the Mitel 5000
DEI product. In this version of software, the serial port is not functional on the
PCDPM, and it does not transmit data, even though the name of the device
suggests that it does.