Specifications

Chapter 6: Programming
Configuring a Single-Port/Dual-Port T1/E1/PRI Module (T1M/T1M-2)
Mitel
®
5000 Installation Manual – Issue 3.0, October 2008 Page 6-121
To “move” a T1M/T1M-2 port:
1. Open the desired database in a local mode session of DB Programming. Make sure the
desired module is explored so the “None” port move location is viewable in the left-hand
tree view.
2. Browse to the module with the existing port you want to move. Click the port, hold down
the mouse button, and drag it over to the tree view. The None port will become
highlighted when the port to be moved is dragged onto it.
3. Drop the port by releasing the mouse button over the desired None port. The port will be
“moved” from the original module to the new module and all of its programming (circuits,
networking, etc.) will be retained. The original module will now have “None” listed as the
port type where the moved port used to be.
When changing a module type from T1M to T1M-2 or vice versa or drag/dropping a port
between module types, the echo profiles for devices programmed on any ports undergoing the
module type transition will be changed to their default type. Refer to the Mitel 5000 Features
and Programming Guide, part number 580.8006, for default echo profiles based on module and
device type. Also, when going from a T1M to a T1M-2 (either changing the module type or drag/
dropping a port) the Span Connection Type port-level field of the Dual T1/E1/PRI ports will be
defaulted to the system companding type.