Specifications

Chapter 6: Programming
Configuring a Basic Rate Module (BRM-S)
Mitel
®
5000 Installation Manual – Issue 3.0, October 2008 Page 6-117
Timers
To program a timer:
1. Select its current Value and enter the new value in the text box.
2. Press ENTER or click on another field to save the change.
The timers are:
Busy No Answer (T301): Applicable to system for Japan only. If the Call Delivered
response (connect message) is not received before this timer expires, the System
disconnects the call.
Call Proceeding (T310): See page 6-125.
Connect Acknowledge (T313): See page 6-125.
Data Link Disconnect (T309): See page 6-125.
Disconnect (T305): See page 6-125.
Idle Link (T203): See page 6-125.
* Overlap Receiving (T302): See page 6-125.
* Overlap Sending (T304): See page 6-125.
Release (T308): See page 6-126.
Restart Acknowledge (T316): See page 6-126.
Resume Acknowledge (T318): See page 6-126.
Retransmit TE1 Request UI Message (T202): Controls the amount of time the ISDN
Data Link layer will wait for a response from the network before it re-transmits a UI frame
during the TEI assignment procedure.
Re-Transmission (T200): See page 6-126.
Setup Request Acknowledge (T303): See page 6-126.
Status Enquiry (T322): See page 6-126.
Suspend Acknowledge (T319): See page 6-126.
XID Request (T204): See page 6-126.
* Currently, the overlap sending/receiving protocols are supported with PRI Net 5 and BRI Net 3
switch types, which are prevalent in the Europe and Mexico markets.
Description
To enter a description:
1. Select the current Value, then enter the description in the text box.
2. Press ENTER or click another field to save the change.
ISDN Switch Type
Basic Rate Module supports AT&T 5ESS Custom, DMS-100, and National ISDN2 switch types.
To change the ISDN switch type setting:
1. Select the current Value, and then use the drop-down list box to scroll to the desired
setting.